GE Simon XT (Versions and sirens)


Hi, I am considering buying a GE Simon XT. I have some questions about it and have done some searching but really can't find the answers. Are there different versions of it and if so does it matter which I buy? I will want to connect a loud an external siren to it. Is this possible? And if so: Easily done for a newbie? Which siren should I buy (what is compatible)? Are wireless sirens an option? Thanks! Here's the manufacturer's site with all the specs and data sheets: Simon XT Few months back i had a terrible experience with this panel. Bought 1 Simon XT unit @ homestoretechnology.com and they refuse to replace or repair within a year.. and send me to manufacturers warranty Hope this helps for those looking for a trustable supplier / alarm panel. Here's the manufacturer store responses: Case: Fwd: Technical Support - HTS (LTK531026526914X) Case Number: 568046 Priority: Medium Status: Closed Date: 08/10/2012 Time: 18:17:42 Creation Date: 08/10/2012 Creation Time: 17:38:17 Created By: axelestrada Description: Entered on 08/10/2012 at 18:17:42 CDT (GMT-0500) by Ralph Strauser: Apologies, but Interlogix does not sell to, nor provide support for end-users. Please contact your security provider. If you do not have one at this time, or cannot determine what company Installed your equipment, please locate the SecurityPro dealer nearest you. A list of them can be found at:Security Pro. If you purchased your system from an online source, contact that company for assistance. Thank You Interlogix Technical Support ---------- Forwarded message ---------- From: Vlad Kosmala


Date: Fri, Aug 10, 2012 at 2:08 PM Subject: RE: Technical Support - HTS (LTK531026526914X) To: axelestrada ** *Reference number:* LTK531026526914X Please use this ticket number in any correspondence with us. *Subject:* Technical Support - HTS Dear Customer, Thank you for contacting us. Based on the video, it appears as though the fault may be with the alarm panel itself. Please contact GE technical support at 888-437-3287 and/or warranty questions. The Simon XT comes with a full year manufacturers warranty. Please feel free to contact us if you have any additional questions. Sincerely, Vlad Home Technology Store 866-523-2146 The company I work for used to install the Simon XT, so I have a limited knowledge of it but am by no means an expert. We now install DSC and I find it too be a much better system, but that's besides the point, on too your questions. There are different versions of it, only two that I've seen, the newer version looks more high tech, it's all white with no door on the buttons. There is an older model with a door that covers most of the buttons. I've only installed the newer version. It does have an output that you can use for a siren or to trigger just about anything else you want. I've only used a GE siren that comes with the Concord system but I would be that most sirens that hook up in a similar way, ie with the positive and negative wires. The Simon does not have a compatible wireless siren's but the DSC Impassa does, and that is part of the reason that I believe it's superior. The DSC just has more options to accommodate more situations with zone types. For example, the Impassa has a Day Zone option. You can arm a safe or even a liquor cabinet and if the alarm is armed, it acts like a normal instant zone, but if the alarm is off, it simply sets off a local alarm, and not the full siren. Go back and read some of the earlier posts on the new XT touchscreen...the one with the door that covers most of the buttons is ancient now XT has 2 outputs, not 1... You can use a Zwave RF siren with the XT (need Alarm.Com for this option)... There are a number of new zone types with the newer versions of the XT, including the zone type described above (Day Zone) Hi- I just purchased a Simon XT w/ GSM module from Safemart to secure a barn on my property in Delaware. The system is being powered by a solar panel array and AGM battery with a 12v DC to 120 VAC power inverter. The stock Simon XT 120 VAC to 9 VAC transformer is plugged into the inverter. As you can see, this a bit of a round-about way to get from 12v DC power to 9 VAC power with all kinds of conversion losses in the middle. I have to think the Simon XT panel is also internally rectifying the 9 VAC power to DC to run the electronics. My question is...the solar controller is capable of outputting 9v DC power. Does the Simon XT use a simple diode bridge rectifier? Is it possible to supply 9v DC power to the Simon XT panel? Would the DC power just flow through the rectifier, or cause problems? Thanks.








Related Posts:




  • How to wire simon xt to relay to drive external sirens

    wire Simon XT to relay to drive external sirensHi, Looking for help on wire a Simon XT to an external siren using a relay. Basically I just want one or two loud sirens, and need to use an external...


  • Ge simon xt with z wave automation

    GE Simon XT with Z Wave AutomationOriginally Posted by wrxman Figured I'll add my question to this existing thread. I have the Simon XT v. 1.3 panel with the Alarm.com GSM module with z-wave. Does...


  • How easy or difficult is it to replace adtvista20p keypad

    How easy or difficult is it to replace ADT/Vista-20P keypad?Hi folks, I've been reading this board but haven't seen an answer to that question - here's the skinny on my situation: 1. Have an ADT b...


  • Ge 250 co detector installation help

    GE 250 CO detector installation - helpI want to install a GE SafeAir 250 CO detector. I have a Carbon Monoxide detector wired into to my home security system and it has reached the end of its life...


  • Following the faq set off the alarm fa130cp fa260 please help

    Following the FAQ set off the alarm... FA130CP + FA260 --- Please Help!I purchased a house about a year ago with a FA260 keypad and an FA130CP alarm system. The former owners did not give us the a...